eCO2 Technologies have developed a wide range of low pressure (LP) cascade, high pressure (HP) cascade and CO2-only racks based on Dorin CO2 compressors, refer to the table below

Product

Type

Dorin

models

Suction temps

Ambient heat reject

eCO Freez

Compound

TCD

LT -50°C to -20°C

Full-time

eCO Cool

1-stage

TCS

MT -20°C to +5°C

Full-time

eCO Duo

2-stage

SCC+ TCS

LT -50°C to -25°C

MT -10°C to +5°C

Full-time

eCO Freez cascade

1-stage

SCS

LT -35°C to -20°C

Option

eCO Cool cascade

1-stage

SCS

MT -20°C to +5°C

Option

eCO Duo cascade

2-stage

SCC+ SCS

LT -50°C to -25°C

MT -10°C to +5°C

Option

eCO Freez LP cascade

1-stage

SCC

LT -50°C to -25°C

No

eCO Freez package

1-stage integral HS

SCC

LT -50°C to -25°C

No

eCO Freez

The eCO Freez racks are CO2-only (HFC-free) units, and operate in sub-critical or transcritical mode, depending on ambient conditions. eCO Freez units offer low temperature (LT) cooling only in a capacity range from 10 to 80kW.  Optional interstage heat recovery provides all year round steady hot water, where required.

eCO Freez

eCO Freez

eCO Cool

The eCO Cool racks are CO2-only (HFC-free) units, and operate in sub-critical or transcritical mode, depending on ambient conditions. eCO Cool units offer medium temperature (MT) cooling only in a capacity range from 20 to 300kW.

eCO Cool

eCO Cool

eCO Duo

The eCO Duo racks are CO2-only (HFC-free) units, and operate in sub-critical or transcritical mode, depending on ambient conditions. eCO Duo units offer both  LT and MT cooling  in a capacity range from 10 to 80kW (LT) and 20 to 250 kW (MT).  eCO Duo units allow evaporators to be switched betwwen LT and MT with ease, very useful for swing cool/freezer rooms. eCO Duo systems are also the most efficient CO2 racks available.  Low temperature compressors are fitted with the efficiency-boosting ESRS system.  Optional interstage heat recovery provides all year round steady hot water, where required.

eCO Duo

eCO Duo

eCO Freez Cascade

The eCO Freez Cascade racks require an additional high stage cooling source, such as chilled water, chilled glycol or direct refrigerant, generally at temperatures < +10deg C.  eCO Freez Cascade units offer low temperature (LT) cooling only in a capacity range from 10 to 80kW.  Optional interstage heat recovery provides all year round steady hot water, where required.

eCO Freez cascade

eCO Freez cascade

eCO Cool Cascade

The eCO Cool Cascade racks require an additional high stage cooling source, such as chilled water, chilled glycol or direct refrigerant, generally at temperatures < +10deg C. eCO Cool Cascade units offer medium temperature (MT) cooling only in a capacity range from 20 to 300kW.

eCO Cool cascade

eCO Cool cascade

eCO Duo Cascade

The eCO Duo Cascade racks require an additional high stage cooling source, such as chilled water, chilled glycol or direct refrigerant, generally at temperatures < +10deg C. eCO Duo Cascade units offer both  LT and MT cooling  in a capacity range from 10 to 80kW (LT) and 20 to 250 kW (MT).  eCO Duo Cascade units allow evaporators to be switched betwwen LT and MT with ease, very useful for swing cool/freezer rooms. eCO Duo Cascade systems are also the most efficient CO2 Cascade racks available.  Low temperature compressors are fitted with the efficiency-boosting ESRS system.  Optional interstage heat recovery provides all year round steady hot water, where required.

eCO Duo Cascade

eCO Duo Cascade

eCO Freez LP Cascade

The eCO Freez LP Cascade  require an additional high stage cooling source, such as chilled glycol or direct refrigerant, generally at temperatures < -5 deg C.  eCO Freez LP Cascade units offer low temperature (LT) cooling only in a capacity range from 10 to 80kW, and are a low cost entry into CO2 refrigeration

eCO Freez LP cascade

eCO Freez LP cascade